Builder Workshops
The
US Department of Energy’s Building
America program will be offering a
special, five-part workshop series for
builders and homeowners involved in
rebuilding Greensburg as a healthy,
energy efficient and affordable town.
Each workshop will include a 1/2-day
tour of current re-construction projects
in Greensburg where participants will
learn about and examine best practice
construction methods. The field visit
will be followed by a 1/2-day in-class
training session lead by residential
construction experts from Building
America project teams.
Schedule & Registration
Greensburg,
Kansas
Building Greensburg - Part 1
Saturday, September 8, 2007
Location
"Public Meeting Room" in the City
temporary offices located at the
southwest corner of the Courthouse
Square
Greensburg, KS
Agenda
The seminar will begin at 9am.
Click here for
a detailed agenda.
Please note that the curriculum
outlined below may change to best
suit the registered participants.
Interested parties are encouraged to
enroll early.
|
Date |
|
Schedule |
Speakers |
| Sept.
8 |
Part
1 |
House Design and Foundation Systems
Course Introduction
Module 1: House Design for a
Mixed-Humid Climate
Module 3: Foundations and Site Work |
Joseph Lstiburek
Building Science Corporation
Alex Lukachko
Building Science Corporation |
| tba |
Part
2 |
Framing
Module 2: Building America Systems
Engineering
Module 4: Framing
Walk-through 1: Foundation
Walk-through 2: Framing |
Joseph Lstiburek
Building Science Corporation
(or)
Alex Lukachko
Building Science Corporation |
| tba |
Part
3 |
Mechanical Systems and Airtightness
Module 5: Water Management
Module 6: Airtightness
Walk-through 2: Framing
Walk-through 3: Airtightness |
Kohta Ueno
Building Science Corporation
Alex Lukachko
Building Science Corporation |
| tba |
Part
4 |
Enclosure
Module 7: Mechanical System Design
and Selection
Module 8: Insulation
Module 9: Exterior Cladding Systems
Walk-through 3: Airtightness
Walk-through 4: Insulation |
Peter Baker
Building Science Corporation
(or)
Alex Lukachko
Building Science Corporation |
| tba |
Part
5 |
Finishes, Testing and Commissioning
Module 10: Measuring Building
Performance
Module 11: Mechanical System
Commissioning
Module 12: Owning an
Energy-efficient Home
Walk-through 4: Insulation
Walk-through 5: Testing and
Commissioning |
Kohta Ueno
Building Science Corporation |
Registration
Follow the link below to register
online for this seminar. There is no
cost for this seminar but registration
is limited to builders, homeowners, and
members of city and state agencies. For
questions about registration, please
call Jeff Melvin at 617-800-2633.
|